What is the cause of abnormal underflow concentration in hydrocyclone?

Author: Time: May 29, 2020 81 views

According to the survey, many customers are using it Hydrocyclone But once there is a problem, I am at a loss and I don't know what to do. It's like a good driver doesn't have to fix it. When looking for repair personnel to repair, they found that the problem was very simple. In many cases, they could solve it by themselves. There was no need to find a professional to repair. The customer was both time-consuming and laborious. According to this situation, the editor decided to summarize the solutions to some common problems, and then share them with you, so as to solve the problems for customers. Today we will introduce the solution to the problem of abnormal underflow concentration in hydrocyclone. Please read the following article.

If the underflow concentration of hydrocyclone exceeds the set value too much, it will have a serious impact on the next production process or product quality. There are many reasons for the abnormal underflow concentration of hydrocyclone. The following are some common ones.

 Hydrocyclone

Operating parameters of Hydrocyclone

The abnormal underflow concentration of hydrocyclone is often caused by excessive deviation between operating pressure or feed concentration and design value. When the operating pressure of hydrocyclone is too low or the feed concentration is too small, the underflow concentration will be low, otherwise, the underflow concentration will be high. It can be solved by adjusting the operating parameters of hydrocyclone.

The size of desilting nozzle of Hydrocyclone

The size of desilting nozzle of hydrocyclone also determines whether the underflow concentration can reach the predetermined value. Hydrocyclones are usually equipped with three sizes of grit nozzles when they are sold. If the sizes of grit nozzles do not meet the actual needs of on-site production, other sizes of grit nozzles can be replaced according to the actual situation, so as to eliminate the abnormal underflow concentration problem.